    实验探究了高频段(1 500~6 500 Hz)柔性微穿孔板吸声体的吸声特性,由于聚氯乙烯(PVC)薄膜具有柔韧性好,黏性不高,易通孔,成本低等特点,因此,该文以PVC为基材,利用阻抗管测试穿孔率分别为2.181%、3.407%、5.436%、7.666%的柔性微穿孔板吸声体的声学性能,并与马氏理论的计算值进行对比。实验结果表明,由于板的振动效应使柔性微穿孔板吸声体的共振峰向低频偏移,且在低频范围内吸声性能提高,高频范围内吸声性能无明显减弱。因此,拓宽了整体的吸声频带宽度,在1 500 Hz时,吸声系数可提高约33.9%。

    Abstract:

    The sound absorption performance of flexible microperforated panel absorber (MPPA) at high frequency range from 1 500~6 500 Hz is investigated experimentally in this paper. Since the polyvinyl chloride (PVC) materials have many advantages such as good flexibility, low viscosity, easytopiercing, low cost, and so on, the PVC is used as the perforated material. The impedance tube is used to test the sound absorption performance of the PVCMPPA with perforation rate of 2.181%、3.407%、5.436%、7.666% respectively, and then compared with Maa′s model. The experimental results show that the absorption peaks due to the panel vibration effect have a low frequency offset. The sound absorption performance of flexible MPPA is improved significantly at lowfrequency range while keeping almost the same at highfrequency range, therefore the frequency band width of sound absorption is widened, and the absorption coefficient increases of about 33.9% at 1 500 Hz.

    参考文献
    相似文献
    引证文献
引用本文

张晓晓, 王焕钦, 孔德义, 钱玉洁, 李国欣, 王兵.柔性微穿孔板吸声体声学性能测试与分析[J].压电与声光,2017,39(5):678-681. ZHANG Xiaoxiao, WANG Huanqin, KONG Deyi, QIAN Yujie, LI Guoxin, WANG Bing. Acoustics Property Measurement and Analysis of Flexible Micro-perforated Panel Absorber[J]. PIEZOELECTRICS AND ACOUSTOOPTICS

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2017-10-10
  • 出版日期: